Remote Monitoring (RMON)
76.1 rmon-alarm
76.1
rmon-alarm
Create a RMON alarm action.
76.1.1

rmon-alarm add

Add RMON alarm.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm add <P-1> [mib-variable <P-2>] [rising-threshold <P-3>]
[falling-threshold <P-4>]
[mib-variable]: MIB variable
[rising-threshold]: Rising threshold
[falling-threshold]: Falling threshold
Paramete
Value
r
1..150
P-1
string
P-2
1..2147483647
P-3
1..2147483647
P-4
76.1.2

rmon-alarm enable

Enable RMON alarm.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm enable <P-1>
Paramete
Value
r
P-1
1..150
698
Meaning
Enter an index that uniquely identifies an entry in the alarm
table.
Enter an object identifier of the particular variable to be
sampled, max. 32 characters.
Enter the rising threshold for the sampled statistic.
Enter the falling threshold for the sampled statistic.