49.1.2

ring-coupling delete

Delete the Ring/Network coupling configuration with the coupling-port index.
Mode: Global Config Mode
Privilege Level: Operator
Format: ring-coupling delete <P-1>
Paramete
Value
r
slot no./port no.
P-1
49.1.3

ring-coupling modify

Modify the Ring/Network coupling configuration with the coupling-port index.
Mode: Global Config Mode
Privilege Level: Operator
Format: ring-coupling modify <P-1> mode <P-2> control-port <P-3> partner-
port <P-4> net-coupling <P-5> redundancy-mode <P-6>
mode: Modify the operating mode.
control-port: Modify the control port (<slot/port>). The control port is only used for outband
configurations.
partner-port: Modify the partner coupling port(<slot/port>). The partner coupling port is only used
for single configuration.
net-coupling: Configure the Ring/Network coupling mode as either network or ring-only.
redundancy-mode: Configure the redundancy mode as either extended or normal.
Paramete
Value
r
slot no./port no.
P-1
single
P-2
dual-master-inband
dual-master-outband
dual-slave-inband
dual-slave-outband
slot no./port no.
P-3
slot no./port no.
P-4
ring-only
P-5
network
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
Meaning
Configure the operating mode of the ring coupling to single.
Both of the coupling ports are local to the switch, switch
performs master and slave functions.
Configure the operating mode of the ring coupling to dual-
master-inband. The second coupling port is on a remote switch,
local switch is master, communication over network.
Configure the operating mode of the ring coupling to dual-
master-outband. The second coupling port is on a remote switch,
local switch is master, communication over dedicated control
port.
Configure the operating mode of the ring coupling to dual-slave-
inband. The second coupling port is on a remote switch, local
switch is slave, communication over network.
Configure the operating mode of the ring coupling to dual-slave-
outband. The second coupling port is on a remote switch, local
switch is slave, communication over dedicated control port.
Select the ring coupling mode for a ring network. Both of the
network segments that are coupled are HIPER rings.
Select the ring coupling mode for a bus or mesh network. The
network segment adjacent to the switches that handle the ring
coupling is not a HIPER ring.
Ring Coupling
49.1 ring-coupling
469

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis