Ring Coupling
49.1 ring-coupling
49.1
ring-coupling
Configure the ring/net coupling settings.
49.1.1

ring-coupling add

Create a new Ring/Network coupling configuration. The configuration consists of default parameters
and the operation is disabled. The interface specified as parameter represents the coupling port.
Mode: Global Config Mode
Privilege Level: Operator
Format: ring-coupling add <P-1> [mode <P-2>] [net-coupling <P-3>]
[redundancy-mode <P-4>] [control-port <P-5>] [partner-port <P-6>]
[mode]: Configure operating mode.
[net-coupling]: Configure the Ring/Network coupling mode as either network or ring-only.
[redundancy-mode]: Configure the redundancy mode as either extended or normal.
[control-port]: Configure the control port (<slot/port>). The control port is only used for outband
configurations.
[partner-port]: Configure the partner coupling port(<slot/port>, The partner couling port is only
used for the for the single configuration mode.
Paramete
Value
r
slot no./port no.
P-1
single
P-2
dual-master-inband
dual-master-outband
dual-slave-inband
dual-slave-outband
ring-only
P-3
network
normal
P-4
extended
slot no./port no.
P-5
P-6
slot no./port no.
468
Meaning
Configure the operating mode of the ring coupling to single.
Both of the coupling ports are local to the switch, switch
performs master and slave functions.
Configure the operating mode of the ring coupling to dual-
master-inband. The second coupling port is on a remote switch,
local switch is master, communication over network.
Configure the operating mode of the ring coupling to dual-
master-outband. The second coupling port is on a remote switch,
local switch is master, communication over dedicated control
port.
Configure the operating mode of the ring coupling to dual-slave-
inband. The second coupling port is on a remote switch, local
switch is slave, communication over network.
Configure the operating mode of the ring coupling to dual-slave-
outband. The second coupling port is on a remote switch, local
switch is slave, communication over dedicated control port.
Select the ring coupling mode for a ring network. Both of the
network segments that are coupled are HIPER rings.
Select the ring coupling mode for a bus or mesh network. The
network segment adjacent to the switches that handle the ring
coupling is not a HIPER ring.
Select the ring coupling mode for normal redundancy mode. The
slave does not respond to a failure in the remote ring or
network.
Select the ring coupling mode for extended redundancy mode The
slave responds to a failure in the remote ring or network.
RM CLI HiOS-3A-MR GRS1040