Paramete
Value
r
emergency
P-1
alert
critical
error
warning
notice
informational
debug
0
1
2
3
4
5
6
7
54.1.17 logging email operation
Enable or disable logging email-alert globally.
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email operation
no logging email operation
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no logging email operation
54.1.18 logging email from-addr
Configure mail address used by device to send email-alert.
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email from-addr <P-1>
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
System is unusable. System failure has occurred.
Action must be taken immediately. Unrecoverable failure of a
component. System failure likely.
Recoverable failure of a component that may lead to system
failure.
Error conditions. Recoverable failure of a component.
Minor failure, e.g. misconfiguration of a component.
Normal but significant conditions.
Informational messages.
Debug-level messages.
Same as emergency
Same as alert
Same as critical
Same as error
Same as warning
Same as notice
Same as informational
Same as debug
Logging
54.1 logging
513