Power Over Ethernet (PoE)
67.1 inlinepower
67.1
inlinepower
Configure the global inline power settings.
67.1.1
inlinepower operation
Configure the global inline power administrative setting (enable or disable, default: enable).
Mode: Global Config Mode
Privilege Level: Operator
Format: inlinepower operation
no inlinepower operation
Disable the option
Mode: Global Config Mode
Privilege Level: Operator
Format: no inlinepower operation
67.1.2
inlinepower slot
Configure the inline power notification (trap), threshold and power budget per slot
Mode: Global Config Mode
Privilege Level: Operator
Format: inlinepower slot <P-1> budget <P-2> threshold <P-3> trap
budget: Configure the inline power budget per slot
threshold: Configure the inline power notification (trap) threshold per slot.
trap: Configure the inline power notification (trap) setting per slot.
Paramete
Value
r
P-1
slot no./port no.
P-2
0..65507
P-3
1..99
618
Meaning
Enter a number in the given range.
Enter a number in the given range.
RM CLI HiOS-3A-MR GRS1040