74.1.3

redundant-coupling role

Set the desired role of the current device inside the RCP.
Mode: Global Config Mode
Privilege Level: Operator
Format: redundant-coupling role <P-1>
Paramete
Value
r
master
P-1
slave
auto
74.1.4

redundant-coupling port primary inner

Set a port as primary ring inner port.
Mode: Global Config Mode
Privilege Level: Operator
Format: redundant-coupling port primary inner <P-1>
Paramete
Value
r
slot no./port no.
P-1
74.1.5

redundant-coupling port primary outer

Set a port as primary ring outer port.
Mode: Global Config Mode
Privilege Level: Operator
Format: redundant-coupling port primary outer <P-1>
Paramete
Value
r
slot no./port no.
P-1
RM CLI HiOS-3A-MR GRS1040
Release 6.1 09/2016
Meaning
Set this device as master RCP device.
Set this device as slave RCP device.
Let the RCP decide the role of this device.