AVENTICS | Bus Coupler AES/Valve Driver AV, EtherCAT | R412018142–BAL–001–AF

12.7 New PLC configuration for the valve system

Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by an electrical specialist!
Observe the specifications of the system owner as well as any restrictions resulting from the
overall system.
Observe the documentation of your configuration program.
After converting the valve system, you need to configure the newly added components. Components
that are still in their original slots (M1) will be detected and do not require a new configuration. If the
data length of the modules on the valve side exceed 4 bytes after conversion, the "4-byte valve
module" may have to be replaced by a "32-byte valve module• in the configuration.
If you have exchanged components without changing their order or quantity, you do not need to
reconfigure the valve system. All components will be recognized by the controller.
For the PLC configuration, proceed as described in section 5 "PLC Configuration of the Valve
System" on page 73.
Conversion of the Valve System
NOTICE
105