7 TROUBLE-SHOOTING

7.1 ALARMS MANAGEMENT
MESSAGGIO
STOP on, MIX blinking,
beater motor off.
STOP on, PRODUCTION
blinking and beater motor off.
MIX blinking and beater
motor off
STOP blinking and beater
motor off
STOP fixed,
CONSERVATION blinking
and beater motor off
All pushbuttons are lighted
up and the beater motor is
off
25 - ENGLISH
DESCRIZIONE
The overload relay has
tripped to protect the beater
motor (possible overheating)
The overload relay (or clixon)
has tripped to protect the
compressor (possible
overheating)
The safety timer has tripped
The CT safety device has
tripped
The safety device protecting
the tank temperature probe
has tripped
The protection device
against voltage drop has
tripped
RIMEDI
Wait for a few seconds and
press the STOP pushbutton
to reset the machine. If the
problem is frequent, call for a
technician.
Wait for a few seconds and
press the STOP pushbutton
to reset the machine. If the
problem is frequent, call for a
technician.
Press the STOP pushbutton
to restore production.
Check for the mixture
balancing and control that
the max. allowable
production is not exceeded.
Press the STOP pushbutton
and try to restart the
machine.
If the signal is still present,
call for a technician
Press the STOP pushbutton
and try to restart the
machine.
If the signal is still present,
call for a technician
Check that the supply
voltage is not 20% inferior to
the nameplate value.
Press the STOP pushbutton
and try to restart the
machine.