Maximum workplace temperature at nominal load
Power derating beyond maximum temperature
Maximum altitude at nominal load
Power derating beyond maximum altitude
Mechanical specifications:
Protection rating
Resistance to vibrations
WARNING
Protect the device from direct exposure to weather and sunlight.
5.2. Energy efficiency
VS POOL 3.5 HP (2.2 kW)
Punto
Frequency [%]
1
0
2
0
3
0
4
50
5
50
6
50
7
90
8
90
9
90
10
100
VS POOL 4.5 HP (3 kW)
Punto
Frequency [%]
1
0
2
0
3
0
4
50
5
50
6
50
7
90
8
90
9
90
10
100
VS POOL 5.5 HP (4 kW)
Punto
Frequency [%]
1
0
2
0
3
0
4
50
5
50
6
50
7
90
8
90
9
90
10
100
18
VS POOL
Current [%]
Relative loss [%]
25
2,13
50
2,34
100
2,84
25
2,16
50
2,39
100
2,94
25
2,18
50
2,44
100
3,04
100
Current [%]
Relative loss [%]
25
2,05
50
2,26
100
2,77
25
2,07
50
2,31
100
2,88
25
2,10
50
2,37
100
2,99
100
Current [%]
Relative loss [%]
25
2,03
50
2,26
100
2,80
25
2,06
50
2,32
100
2,91
25
2,09
50
2,37
100
3,04
100
40°C (104 °F)
-2.5% every °C (-1.4% every °F)
1000 m (3280 ft)
- 1% every 100 m (328 ft)
IPX5
EN 60068-2-6:2008, EN 60068-2-27:2009, EN 60068-2-64:2008
Absolute loss [W]
88,56
97,36
118,13
89,66
99,54
122,29
90,60
101,47
126,30
Absolute loss [W]
113,44
125,31
153,45
114,92
128,29
159,36
116,23
131,13
165,63
Absolute loss [W]
126,79
140,76
174,29
128,60
144,42
181,65
130,18
147,85
189,25
Efficiency [%]
50,85
64,52
73,55
83,63
89,89
93,57
90,10
94,01
95,90
96,30
Efficiency [%]
51,85
65,32
74,04
84,16
90,19
93,72
90,43
94,18
95,96
96,35
Efficiency [%]
52,01
65,36
73,86
84,24
90,19
93,68
90,48
94,18
95,91
96,30