Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Inspection On Delivery; Handling; Storage - Astralpool Vs Pool Sicherheits- Und Schnellstartanleitung

Inhaltsverzeichnis

4.1. Transport

Avoid subjecting the product to severe shocks or extreme weather conditions during transport. The packaging must remain dry and at a temperature between -20°C
(-4°F) and +70°C (+158°F). Do not stack packages without first checking feasibility with the manufacturer.
TIP
It is advisable to always indicate FRAGILE on the packaging

4.2. Inspection on delivery

Upon receipt of the product, check:
• the integrity of the packaging
• the integrity of the content
• the presence of all components
In case of problems, notify the forwarder immediately.
WARNING
The manufacturer declines all responsibility for damage to the product due to transport

4.3. Handling

The product must be handled by hand or using suitable lifting equipment in relation to its weight and the regulations in force.
If necessary, use dedicated handling equipment (cranes, ropes, trolleys), using the lifting points provided in the product.
During handling it is recommended to:
• Handle with care
• keep away from suspended loads
• always wear accident prevention equipment
• be careful not to damage electrical cables
Do not handle the product using electrical cables as lifting gear.
WARNING
Failure to follow the instructions may result in damage to the product, the system in which it is installed and, in the worst cases, damage to
property or persons with even fatal consequences.

4.4. Storage

The product must be stored in its packaging in a dry place, without sudden changes in humidity and temperature and protected from mechanical (weights,
vibrations), thermal and chemical agents.
The temperature of the storage environment must be between -20°C (-4°F) and 70°C (+158°F) with a maximum relative humidity of 85% (non-condensing).
If the product remains in stock for more than 24 months from the manufacturing date shown on the packaging, it is necessary to check the mechanical integrity of its
parts and supply power to it at least once every 12 months.
If the product is put back into storage after it has been used, it is advisable to contact the manufacturer for further information on storage.

5. Technical features

5.1. Technical Data

Electrical specifications by model:
Code
Model
73773-4010
VS POOL P 3.5 HP
73774-4010
VS POOL P 4.5 HP
73775-4010
VS POOL P 5.5 HP
77257
VSPOOL S 2,2kW
77258
VSPOOL S 4kW
Devices VS POOL P are supplied already mounted on motor and motor parameters are therefore already defined in the firmware.
Devices VS POOL S can be mounted on wall, using special fixing kit included in the package, and control other pool pumps after appropriate programming of motor
parameters.
General electrical specifications:
Power supply frequency
Voltage unbalance between the power supply phases
Maximum output frequency
EMC compliance
Energy efficiency class (according to EN61800-9-2)
Bluetooth transmission power / Operating frequency bands
Environmental specifications:
Relative humidity of the operating environment
Workplace temperature
Vin +/- 15% [VAC]
Max V out [VAC]
3 x 380 - 460
3 x Vin
3 x 380 - 460
3 x Vin
3 x 380 - 460
3 x Vin
3 x 380 - 460
3 x Vin
3 x 380 - 460
3 x Vin
VS POOL
Max I in [A]
Max I out [A]
5,4
6
7,2
8
8
9
5,4
6
8
9
50 / 60 Hz (+/- 2%)
+/- 2%
300 Hz
EN 61800-3 C2
IE2
max 7.5 dBm / 2410MHz - 2480MHz
5 - 95 % non-condensing
from -10 °C (14 °F) to 60 °C (140 °F)
Typical motor P2 [kW]
η
[%]
max
2,2
96
3
96
4
96
2,2
96
4
96
Size
1
1
1
1
1
17