GARANT XControl
de
T1234
Change tool.
⁝
NC program
⁝
Tool positioning 5 mm above the XControl.
en
Back to Heidenhain automatic operation [} Page 14]
6.4.5.
Auxiliary cycle L_RESET
Probe cycle Function
bg
L_RESET
After 100 probe pro-
cesses, the wireless
connection is deactiv-
da
ated. The reactivation
of the wireless con-
nection is automatic
upon call-up of a
fi
probe cycle, but takes
approx. 15 seconds.
Through call-up of the
auxiliary cycle, the
counter of the meas-
fr
urements is reset and
the wireless connec-
tion is maintained.
Example/program code: CALL PGM TNC:\X_CONTROL\L_RESET_XC.H ;
it
Back to Heidenhain automatic operation [} Page 14]
7.
Error messages
hr
Error code
Fault
#1010
WIRELESS SIG-
NAL MISSING
lt
nl
#1070
MEASUREMENT
no
NOT CORRECT
pl
#1085
REFERENCE
pt
LENGTH DOES
NOT MATCH
TOOL LIST
ro
#1095
DISTANCE
FROM TOOL TO
BREAKAGE
sv
MONITORING
TO LARGE
#1105
TOOL BREAK-
AGE
sk
#1115
LENGTH NOT
PLAUSIBLE OR
SWARF NEST
sl
#1125
FEED RATE
FACTOR /
es
MEASUREMENT
RATE TOO HIGH
cs
#1135
TOOL LENGTH
NOT PLAUSIBLE
hu
16
Note
Program code
L_RESET
Possible cause Action
Performed by
Wireless con-
Carry out reset.
Trained special-
nection
ist for mechan-
Check whether
between the
ical work
measuring
stick and the
device is within
probe device
wireless range.
cannot be es-
tablished.
Reconnect USB
stick.
Check battery.
Sensor value on
Carry out reset.
Trained special-
probe device
ist for mechan-
Clean the sur-
after repeated
ical work
face or meas-
positioning
urement
>0.01 or <-0.01.
sphere.
Tighten meas-
urement
sphere.
L_POS: Differ-
Carry out reset.
Trained special-
ence between
ist for mechan-
Correct the tool
length specific-
ical work
length in the in-
ation in the tool
put mask.
memory and
the input mask.
Tool start posi-
Carry out reset.
Trained special-
tion >8 mm in
ist for mechan-
Correct the start
front of break-
ical work
position of Z-.
age monitoring.
Tool broken.
Carry out reset.
Trained special-
ist for mechan-
Replace tool.
ical work
Cause could be
Remove swarf.
Trained special-
due to swarf or
ist for mechan-
Check whether
the tool has
ical work
the tool has
been pulled out
been pulled out
of the holder.
of the holder.
Measurement
Carry out reset.
Trained special-
feed rate in in-
ist for mechan-
Reduce meas-
put mask too
ical work
urement feed
high Maximum
rate.
feed rate factor
= 3 / =>
1500 mm/min.
L_BREAK:
Carry out reset.
Trained special-
length read out
ist for mechan-
Check tool
of tool memory
ical work
length in con-
not plausible.
troller.
#1145
INCORRECT
L_LENGTH:
MODE IN INPUT
Value in input
MASK
mask is not 0 or
1.
#1155
BREAKAGE
The tool that is
MONITORING
to be mon-
ALREADY AC-
itored for break-
TIVATED
age already
touches the
TOOL CHECK
upon program
start.
#1160
BATTERY
Battery flat.
VOLTAGE TOO
LOW
#1170
SENSOR VALUE
Sensor value
NOT PLAUSIBLE
smaller than 2.1
or greater than
4.5 mm.
#1180
USB REBOOT
WIRELESS CON-
FAILED = RE-
NECT has not
CONNECT USB
registered des-
STICK
pite NC com-
mand.
#1195
LOW BATTERY
Low battery.
X_CONTROL_1
#2005
LOW BATTERY
Low battery.
X_CONTROL_2
8.
Cleaning
Clean with a cloth or compressed air.
Do not use any corrosive cleaning agent.
9.
Maintenance
The XControl is maintenance-free.
10. Decommissioning
Clean Xcontrol thoroughly and remove batteries.
11. Storage
Store in an enclosed dry room.
Do not store in the vicinity of acidic, aggressive, chemical substances, solvents, hu-
midity and dirt.
Protect against direct sunlight.
Store at temperatures between +15° C and +35 °C.
Relative atmospheric humidity max. 60%
12. Disposal
Comply with the national and regional environmental protection
and disposal regulations for correct disposal or recycling. Segreg-
ate items into metals, non-metals, composite materials and con-
sumables and dispose of them responsibly. Re-use is preferable to
disposal.
Do not dispose of batteries in domestic waste.
Use return and collection systems to dispose of batteries.
13. EU/UK declaration of conformity
Hoffmann Supply Chain GmbH hereby declares that this wireless device complies
with Directive 2014/53/EU and the UK Radio Equipment Regulations 2017. The com-
plete text of the declaration of conformity is available at hoffmann-group.com/ser-
Check differ-
ence between
tool tip and tool
setting dimen-
sion D1 in input
mask yy. D1
length is
checked.
Check correct-
ness of position
determination
of the XC with
L_POS.
Carry out reset.
Trained special-
ist for mechan-
Change mode
ical work
in input mask:
0 = only meas-
ure tool length.
1 = overwrite
tool length.
Carry out reset.
Trained special-
ist for mechan-
Correct the start
ical work
position of Z+.
Carry out reset.
Trained special-
ist for mechan-
Change the
ical work
battery.
Carry out reset.
Trained special-
ist for mechan-
Remove and re-
ical work
insert the bat-
tery.
Carry out reset.
Trained special-
ist for mechan-
Reconnect USB
ical work
stick.
Change the bat-
Trained special-
tery.
ist for mechan-
ical work
Change the
Trained special-
battery.
ist for mechan-
ical work