The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical knowl-
edge or skill is required, and so they must only
be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of
operation.
Fault
The heating elements do
not come on
The appliance does not heat
up to the set temperature
The control panel does not
come on
GB
Alarm
E00
Start the cooking well probe
E01
Start the cooking well probe
E.01
3301300_ut_GB_rev.1
Electrical connection not
Safety thermostat tripped
Contactor not receiving elec-
Electronic circuit board not
receiving electrical power
TABLE OF ALARM INDICATIONS
Cause
Safety thermostat failure
(left well)
(left well)
FAULT
TROUBLESHOOTING
Important
For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Cause
made correctly
trical power or faulty
The appliance's functions are disabled so no cooking
cycles can be carried out. Reset the safety thermostat
(see page12), if the problem persists, call the after-
The appliance's functions are disabled so no cooking
Contact the after-sales service.
The appliance's functions are disabled so no cooking
Contact the after-sales service.
- 16 -
Remedy
Check the connection of the
electrical wires
Carry out the appliance reset (see
page 12)
Check the condition of the
thermostat and activate any
ignition enabling device
Check or replace the contactor
coil
Check or swap the phase wire
connections
Remedy
sales service
cycles can be carried out.
cycles can be carried out.
ENGLISH