Herunterladen Diese Seite drucken

Hettich BlueMax Mini Typ 3 Betriebsanleitung Seite 54

Vorschau ausblenden Andere Handbücher für BlueMax Mini Typ 3:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Description of the machine
4. Description of the machine
1. Technical specifications
2. Controls
3. Setting up
4. Safety guards
5. Labelling
en
54
All manuals and user guides at all-guides.com
1. Technical specifications
54
55
55
55
56
Designation:
Automatic drilling and insertion machines
for panel type workpieces
Machine no.:
Year of manufacture:
System dimensions:
Height:
630 mm
Width:
800 mm
Depth:
620 mm (with suction extractor)
Weight:
33.5 kg
max. noise level:
> 89 dB (A)
Electrics
The unit is fitted with a connection cable of approx. 3 m
in length and plug (refer to table for configuration).
For your own safety, please instruct a qualified electrician
to connect the machine. You will find the applicable
connection specifications on the rating plate on the
machine.
Motor overview - BlueMax Mini Type 3:
Volts (V)
Phases (Ph)
Hertz (Hz)
Power (kW)
Speed (rpm)
400 V
3 ph.
50 Hz
1.1 kW
2,800 rpm
230 V
1 ph.
50 Hz
1.1 kW
2,850 rpm
230 V
3 ph.
60 Hz
1.3 kW
3,400 rpm
230 V
1 ph.
60 Hz
1.3 kW
3,400 rpm
Requirements on the electrical power supply
Connection must only be made to an electrical system com-
plying with VDE 0100. The electrical safety of this equip-
ment is only guaranteed if it is connected to a protective
earth conductor system that complies with regulations. It is
very important to check that this basic safety requirement
is met and that the machine is provided with adequate fuse
protection. The manufacturer cannot be held responsible for
damage caused by a lacking or interrupted protective earth
conductor. The rating plate provides information on rated
input and the appropriate fuse protection.
Pneumatic connection
The automatic drilling machines have a fitted coupler plug,
nominal width 7.2
• Max. input pressure 6-7 bar / 100 PSI
• Air consumption per stroke 1.2 l
Suction extractor
It is compulsory to use a flexible, fire retardant hose for
connection to an extractor system. A suction extraction line
is not included.
• Outside diameter (suction connector)
• Volumetric flow
• Static negative pressure at 20 m/s
Version
Connection data
Type 3
CEE plug
EPS
ready to connect
Shockproof
(Schuko) plug
EPS
ready to plug in
Machine must
be connected to the local
EPS
mains power supply by a
qualified electrician
Machine must
be connected to the local
EPS
mains power supply by a
qualified electricia
50 mm
141 m/3/h
1,300 Pa

Werbung