Instructions for Behnke Hybrid series 20-0005-BS, SIP intercoms series 20-0005B-IP
GB
Mounting
4. Keypad ▸ connect the HPI contacts marked
A/B/C/D to the terminals T5/T6/T7/T8 on the
connection board in the junction box.
5. Behnke USB camera ▸ Connect the Behnke
USB camera directly to the USB port of the
SIP intercom station. Please note: For more
information, refer to the matching instruc-
tions for this product. The SIP station must be
de-energised when connecting this compo-
nent. This function is only available if the
intercom station has a network connection.
6. Behnke IP camera
Connect the Behnke IP camera to the switch
port of the SIP intercom station (only possible
for 20-0005-BS). This function is only availa-
ble if the intercom station has a network
connection.
7. If necessary, connect the door opener to the
relay of the connection board in the junction
box. (Relay = voltage-free contact: only
switches the door opener circuit, does not
supply it with electrical voltage. Please use
the normally open contact). The door opener
requires its own circuit. Relay 2 (only on
basic electronics 20-0005-BS, 20-0005B-IP)
is available for further switching functions.
Relay activation of relay 1 in the delivery state
of the SIP intercom station: 0#
8. Behnke hearing loop
Connect the Behnke hearing loop to the
corresponding port on the basic electronics.
When operating the Behnke hearing loop, the
microphone unit requires PoE +
60
Important: the cable lengths of the connected
components such as loudspeaker, microphone,
keys and keypad must not exceed a length of
2.50m to the junction box 43-9251-BS.
When extending the connecting cable, use the
suitable Behnke extension cables 20-9305-BS,
20-9311 (keypad).
Connect the hybrid / SIP intercom station to
your on-site network infrastructure or to the ana-
logue telephony infrastructure in compliance
with the relevant standards and regulations. For
more information, see section 4 of this manual.
Please note: PoE class0 is required!
When operating the intercom station with the
Behnke hearing loop, PoE+ is mandatory.
9. When connecting LS, Mik and a button via
connection cable 20-9309, observe the ins-
tallation instructions on p. 16, item 3.3.