Herunterladen Inhalt Inhalt Diese Seite drucken

Eingänge - primes FocusParameterMonitor FPM 60 Originalbetriebsanleitung

Hardware- und softwareinterface profinet / profibus
Vorschau ausblenden Andere Handbücher für FocusParameterMonitor FPM 60:
Inhaltsverzeichnis

Werbung

PROFIBUS®-/PROFINET®-Parametersatz
8.1
Eingänge
FPM
In
"Version
256
(read only)"
258
262
266
268
270
"Konstanten
(read only)"
272
274
276
278
280
282.0
282.1
282.2
282.3
282.4
282.5
282.6
282.7
Status (read
only)
283.0
283.1
283.2
283.3
283.4
283.5
283.6
283.7
284.0
284.1
284.2
284.3
"PMM
StatusSys-
284.4
tem"
284.5
284.6
284.7
285.0
285.1
285.2
285.3
"PMM
StatusShutter"
285.4
285.5
285.6
285.7
StatusReserve
286
Revision 07 DE 10/2022
FPM mit
FPM neu
Kaustik-
Kaustik-
Option
Option
Adresse
256
256
Device / Software revision
PMM constant: maximal
258
258
capacity
262
262
PMM constant: minimal energy
PMM constant: min. irradiation
266
266
time
PMM constant: max. irradiation
268
268
time
270
270
PMM constant: maximal power
PMM constant: minimal absor-
272
272
ber temperature
PMM constant: maximal absor-
274
274
ber temperature
PMM constant: pulse duration
276
276
measurement available
278
278
PMM constant: device type
280
280
PMM constant: release
282.0
282.0
Ready for Measurement
282.1
282.1
Measurement running
282.2
282.2
Measurement finished
282.3
282.3
Measurement failure
282.4
282.4
Idle
282.5
282.5
Irradiation failure
282.6
282.6
Start acknowledge
282.7
282.7
Setup Params read
283.0
283.0
Caustic measurement running
283.1
283.1
Caustic measurement finished
283.2
283.2
Caustic measurement failure
283.3
283.3
283.4
283.4
283.5
283.5
283.6
283.6
283.7
283.7
284.0
284.0
PMM status: ready
284.1
284.1
PMM status: running
284.2
284.2
PMM status: finished
284.3
284.3
PMM status: too hot
284.4
284.4
PMM status: idle
284.5
284.5
PMM status: irradiation failure
284.6
284.6
PMM status: start acknowledge
PMM status: shutter acknow-
284.7
284.7
ledge
285.0
285.0
PMM status: shutter is open
285.1
285.1
PMM status: shutter is closed
285.2
285.2
PMM status: shutter is moving
285.3
285.3
PMM status: shutter timeout
PMM status: error shutter
285.4
285.4
anglesensor
285.5
285.5
285.6
285.6
285.7
285.7
286
286
Einheit /
Län-
Wieder-
Typ
ge
holrate
fix
2 byte word
4 byte Dword
4 byte Dword
2 byte word
2 byte word
2 byte word
2 byte word
2 byte word
2 byte word
2 byte word
2 byte word
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
1 byte
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
> 1Hz
bool
bool
1 byte
bool
bool
bool
bool
bool
bool
bool
bool
1 byte
bool
bool
bool
bool
bool
bool
bool
bool
1 byte
bool
bool
bool
bool
2 byte word
Vor-
zei-
chen
31

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis