Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Hours Counter - Balluff BIS M-4A3-082-401-07-S4 Anleitung

Industrial rfid-system
Vorschau ausblenden Andere Handbücher für BIS M-4A3-082-401-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
5
Secondary Device Functions (continued)
5.2

Operating Hours Counter

5.2.1
Description
The operating hours counter can record the operating
hours of a device accurately to the second. There are a
total of three operating hours counters. In addition to an
operating hours counter for the operating hours since the
start of the device, there is a total operating hours counter
and a customer-specific operating hours counter that can
be reset. The storage rate is adjustable and there is no
saving of the operating hours when 1,000,000 storage
cycles are reached.
5.2.2
Algorithm
While the counter is incremented every second, the
storage rate doubles after each save operation. Starting
with a save operation after 1 minute, then after 2 minutes,
then after 4 minutes, then after 8 minutes, until a maximum
storage rate of every 12 minutes.
5.2.3
Process Data
Object ID
Name
0x001B (27)
Current Operating Hours
0x001C (28)
Total Operating Hours
0x001D (29)
Custom Operating Hours
Tab. 5-10: Operating hours counter – Process data
5.2.4
ISDU
Name
Current Operating Hours
Total Operating Hours
Custom Operating Hours
Operating Hours Saving Mode
Tab. 5-11: Operating hours counter – ISDU
The maximum counter value that can be saved is
1,000,000 and, with a switch-on and switch-off
every 12 minutes (with static counter), means a
service life of over 20 years.
If switched on and off more frequently or in the
case of dynamic storage, the maximum storage
time is reduced depending on the application.
www.balluff.com
Description
Output of the current operating hours counter
Output of the total operating hours counter
Output of a user-defined operating hours counter
Index
Sub-
Access Length
index
0x0057 (87)
1
R
0x0057 (87)
2
R
0x0057 (87)
3
R
0x0074 (116)
0
R/W
The output of the operating hours can serve as a time
control for the service interval as well as for preventative
maintenance. Schedules for regular service can be tied to
the operating hour values. Moreover, a high value of the
total operating hours is indicative of intensive use of a
sensor and possible deterioration of the performance. The
risk of failure can be countered preventatively through
replacement.
Data Type
4 Byte
UINT32
4 Byte
UINT32
4 Byte
UINT32
1 Byte
ENUM
Direction
Input
Input
Input
Data
Default
Storage
No
0
No
0
No
0
Yes
0
english
29

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis