Secondary Device Functions (continued)
5.6
Internal Temperature
5.6.1
Description
The sensor is equipped with internal temperature
monitoring. This records the device temperature as well as
the maximum and minimum values during production and
since the last time the sensor was restarted.
An upper and a lower threshold value can be defined for
the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or
undercut, the senor triggers IO-Link events.
5.6.2
Process Data
Object ID
Name
0x0050 (80)
Device Temperature
Tab. 5-26: Internal temperature – Process data
5.6.3
ISDU
Name
Device Temperature
0x0052 (82)
Device Temperature
Minimum Device
Temperature Since
Reset
Maximum Device
Temperature Since
Reset
Lifetime Minimum
Device Temperature
Lifetime Maximum
Device Temperature
Device Temperature
0x0053 (83)
Alarm Configuration
Lower Alarm Level
Device Temperature
Upper Alarm Level
Device Temperature
Tab. 5-27: Internal temperature – ISDU (overview)
36
english
Description
Current device temperature in °C.
Index
Sub index
Access
0
R
1
R
2
R
3
R
4
R
5
R
0
R/W
1
R/W
2
R/W
Length
Data Type
Data Storage
10 Byte
INT16[]
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
4 Byte
INT16[]
2 Byte
INT16
2 Byte
INT16
Direction
Output
Default
Yes
No
No
No
No
No
Yes
No
−5
No
BIS M-4A3-...: 80
BIS M-4A6-...: 92
BIS M-4A7-...: 90
BIS M-4A9-...: 80

Werbung