BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
6
System Functions (continued)
6.5
LED Meaning and Configuration
6.5.1
Description
Only the signal with the highest priority is displayed. The
signals are listed in descending priority.
Balluff Standard (as-delivered state)
(BIS M-4A3-082-401-07-S4
BIS M-4A6-082-401-07-S4
BIS M-4A7-082-401-07-S4)
Name
Ping
Short Circuit Pin 2 / Pin 4
Failure
Teach In
Maintenance Required
Bad Signal Quality
Out of Specification
Data Carrier Access Active
Function Display
Communication
Ready Diagnosis On
Tab. 6-15: LED meaning and configuration – Balluff Standard
52
english
Signal
Blue, flashing, 3 Hz
Red, flashing, 3 Hz
Red, static
Red, static
Blue, static
Orange, flashing, 1 Hz
Yellow, flashing, 3 Hz
Static white
Yellow, alternating with
green in a ratio of 10:1, 1 s
period
Green, alternating with
LED off in a ratio of 10:1,
1 s period
Green, static
Meaning
The ping can be activated via a system command to find
the device again.
Short circuit at pin 2 or pin 4
General error
The sensor is currently in Teach-In mode
Maintenance must be performed. Threshold value of
inclination is exceeded (default: Function switched off).
Poor signal quality (number of bad data carrier accesses)
The device is operated outside of specifications.
Data carrier communication (read or write)
CP signal (data carrier within RFID range)
IO-Link communication is active. The device is ready.
The device is ready. Diagnosis functions are on.