Overview of IO-Link Data and Functions (continued)
Name
Index
Voltage Monitoring
0x2200
Detection Time
(8704)
Duration
Lifetime Extreme
0x00D0
Thresholds
(208)
Threshold Vibration
Upper Threshold
Temperature
Lower Threshold
Temperature
Lifetime Extreme
0x00D1
Status
(209)
State
Time
Device Temperature
0x0052
Device Temperature
Minimum Device
Temperature Since
Reset
Maximum Device
Temperature Since
Reset
Lifetime Minimum
Device Temperature
Lifetime Maximum
Device Temperature
Device Temperature
0x0053
Alarm Configuration
Lower Alarm Level
Device Temperature
Upper Alarm Level
Device Temperature
www.balluff.com
Sub-
Access
index
Voltage and Current Monitoring
0
R/W
Extreme Environment Status
0
R/W
1
R/W
2
R/W
3
R/W
0
R
1
R
2
R
Internal Temperature
0
R
(82)
1
R
2
R
3
R
4
R
5
R
0
R/W
(83)
1
R/W
2
R/W
Length
Data Type
Storage
2 bytes
UINT16
8 Byte
4 Byte
FLOAT
2 Byte
INT16
2 Byte
INT16
5 Byte
1 Byte
ENUM
4 Byte
UINT32
10 Byte
INT16[]
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
2 Byte
INT16
4 Byte
INT16[]
2 Byte
INT16
2 Byte
INT16
Data
Default
Yes
10
Yes
No
100.0
No
BIS M-4A3-...: 80
BIS M-4A6-...: 92
BIS M-4A7-...: 90
BIS M-4A9-...: 80
No
−5
No
No
No
Yes
No
No
No
No
No
Yes
No
−5
No
BIS M-4A3-...: 80
BIS M-4A6-...: 92
BIS M-4A7-...: 90
BIS M-4A9-...: 80
english