Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS M-4A3-082-401-07-S4 Anleitung Seite 98

Industrial rfid-system
Vorschau ausblenden Andere Handbücher für BIS M-4A3-082-401-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
5
Secondary Device Functions (continued)
5.7
Inclination and Installation Aid
5.7.1
Description
This feature offers two functions:
1. Inclination detection
2. Installation and alignment aid
The function detects the inclination (shift) of an installed
IO-Link device.
The deflection can be rotation, inclination or movement.
With this function, the inclination (green arrow) can be
detected but not others (red arrows).
Measurement range: 0...180°
Resolution: 1°
Accuracy: +/-1°
Measurement period: 1000 ms (data refresh rate =
1 second)
Fig. 5-4:
Different displacements
Using the feature
1. Switch on, establish IO-Link communication.
2. Send system command 0xC0.
⇒ The inclination measurement data is available via
ISDU (e.g., 0x2154) or via the process data.
Fig. 5-5:
Overview of the alarm function
38
english
5.7.2
Mathematics/Algorithm
With this function, the inclination deviation (angle)
describes the inclination of the IO-Link device compared to
its original or reference installation position. The reference
orientation can be arbitrary; this means that the installation
position can be arbitrary. The inclination deviation is
compared neither directly with the horizontal plane nor
with the vertical gravitational field, but rather with the
orientation taught-in by the end user.
In summary:
Inclination deviation = absolute value of (taught-in
reference orientation – actual orientation)
Values: 0...180
Unit: Degrees (°)
As an auxiliary function, the function can detect whether
the device has lost its original position. The configuration
can be performed via ISDU parameters (see section ISDU
on page 39).