Industrial RFID-System BIS M
5
Secondary Device Functions (continued)
Threshold Vibration
Threshold value for the detection of excessive vibrations.
Upper Threshold Temperature
Threshold value for the detection of excessive temperature.
Lower Threshold Temperature
Threshold value for the detection of temperature that is too
low.
State
The current status can be read under State.
Bit
Name
Description
0
Vibration
The vibrations are above the
threshold value.
1
Upper
The temperature is above the
Temperature
threshold value.
2
Lower
The temperature is below the
Temperature
threshold value.
Tab. 5-23: Extreme environment status – State
Time
Under Time, the summed time in seconds in which the
device was exposed to an extreme condition can be read
out.
5.5.6
System Commands
Command Value Device Action
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets
writable parameters to the default
value.
0xA5 (165)
Maintenance Reset – Resets the
value for Time and Flags.
Tab. 5-25: Extreme environment status – System Commands
For an overview of all System Commands, see section 3.4
on page 14.
www.balluff.com
5.5.5
Events
Event
Event
Description
Code
Type
0x8D13
Warning
One or more
(36115)
extreme conditions
present.
Tab. 5-24: Extreme environment status – Events
Device
Status
0 – Device is
operating
properly.