BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
5
Secondary Device Functions (continued)
5.5
Extreme Environment Status
5.5.1
Description
With the help of the Extreme Environment Status, the time
is recorded in which the device was exposed to extreme
conditions. In parameter Lifetime Extreme Thresholds, limit
values can be configured for the respective conditions.
Parameter Lifetime Extreme Status can be used to read
out the current status as well as the summed time.
5.5.3
Process Data
Object ID
Name
0x0041 (65)
Lifetime Extreme
0x0042 (66)
Lifetime Extreme Time
Tab. 5-21: Extreme environment status – Process data
5.5.4
ISDU
Name
Index
Lifetime
0x00D0 (208)
Extreme
Thresholds
Threshold
Vibration
Upper
Threshold
Temperature
Lower
Threshold
Temperature
Lifetime
0x00D1 (209)
Extreme
Status
State
Time
Tab. 5-22: Extreme environment status – ISDU
34
english
Description
One or more extreme conditions present.
Combined total time in which the device was exposed to an
extreme condition.
Sub index
Access
Length
0
R/W
1
R/W
2
R/W
3
R/W
0
R
1
R
2
R
5.5.2
Mathematics/Algorithm
If one (or more) extreme conditions are met, the device
begins to record the time.
If the power supply is interrupted during this time,
the time counter can have an error of maximum
180 seconds.
Data Type
Data
Storage
8 Byte
4 Byte
FLOAT
2 Byte
INT16
2 Byte
INT16
5 Byte
1 Byte
ENUM
4 Byte
UINT32
Direction
Input
Input
Default
Yes
No
100.0
No
BIS M-4A3-...: 80
BIS M-4A6-...: 92
BIS M-4A7-...: 90
BIS M-4A9-...: 80
No
−5
No
No