Secondary Device Functions (continued)
Device Temperature
Device Temperature contains information about the device
temperature (current value in °C), the minimum or
maximum device temperature since the last time the
device was switched on/reset (in °C) and minimum or
maximum device temperature during the lifetime of the
device (in °C).
Device Temperature Alarm Configuration
Setting for the lower threshold value (in °C) for the device
temperature warning (0x8D20) and upper threshold value
(in °C) for the device temperature warning (0x8D10).
5.6.4
Events
Event Code
Event Type
0x4000 (16384)
Error
0x4210 (16912)
Warning
0x4220 (16928)
Warning
0x8D10 (36112) Warning
0x8D20 (36128) Warning
Tab. 5-28: Internal temperature – Events
www.balluff.com
Description
Temperature fault – overload – The device is operated
outside of the device-specific temperature limits. Risk of
device damage.
Device temperature overrun – clear heat of source – risk
of device damage. The device is too hot.
► Remove heat source, provide the device with heat
insulation if necessary.
Device temperature underrun – insulate device – risk of
device damage. The device is too cold.
► Insulate the device.
Device temperature upper warning – The set upper
temperature warning threshold has been exceeded.
Device temperature lower warning – The set lower
temperature warning threshold is below the minimum
value.
Device Status
4 – Failure
2 – Out-of-Specification
2 – Out-of-Specification
0 – Device is operating properly