BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
6
System Functions (continued)
6.2.4
Events
For an event overview, see section 3.5 on page 15.
Event Code Suppression
This parameter indicates the currently suppressed event
messages. The user can access the individual messages
via Sub index 0 or a specific Sub index. This index is part of
the data storage and is stored in non-volatile memory.
Value 0x0000 (0) is the default value and is interpreted as
FREE.
Each event message is structured as follows:
Byte1 (MSB – sent first)
Event Code High Byte
Tab. 6-6:
Diagnosis suppression – Event Message Suppression
Event Code Suppression Teach-In/Delete
To add an event to the list of suppressed events, the event
code is inserted in Sub index 0 in Event Code Suppression
Teach-In. It is added to the next free place in the table.
If the event code is deleted with Event Code Suppression
Delete, it is removed from the list.
48
english
Byte0 (LSB)
Event Code Low Byte