Secondary Device Functions (continued)
5.1.4
ISDU
Minimum, Maximum, Average and Moving
Average outputs are output in FLOAT32 format.
Before they are processed further and converted
from FLOAT32 to INT32 or UINT32, the output
signal must be checked to determine whether it
is larger than int32_Max or uint32_Max. If it is
larger, data type UINT64 or INT64 should be
used.
Name
Index
Statistics
0x0426
Data
(1062)
Configuration
Input Signal
Time Period
Unit
Time Period
Value
Moving
Average
Window Unit
Moving
Average
Window
Value
Statistics
0x0427
Data Output
(1063)
Minimum
Maximum
Average
Moving
Average
Number of
samples
Status
Tab. 5-2:
Basic statistics – ISDU
Statistics Data Configuration: Input Signal
All data types of process data objects can be used for
input configuration, with the exception of Boolean. The
respective Object IDs can be found in the respective
section on the function.
26
english
Sub index
Access
0
R/W
1
R/W
2
R/W
3
R/W
4
R/W
5
R/W
0
R
1
R
2
R
3
R
4
R
5
R
6
R
Length
Data Type
8 Byte
2 Byte
ENUM
1 Byte
ENUM
2 Byte
UINT16
1 Byte
ENUM
2 Byte
UINT16
21 bytes
4 Byte
Float32
4 Byte
Float32
4 Byte
Float32
4 Byte
Float32
4 Byte
UINT32
1 Byte
UINT8
Data
Default
Storage
Yes
No
No
Seconds
No
1
No
Measurement
values
No
100
No
No
0
No
0
No
0
No
0
No
0
No
0

Werbung