Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS M-4A3-082-401-07-S4 Anleitung Seite 74

Industrial rfid-system
Vorschau ausblenden Andere Handbücher für BIS M-4A3-082-401-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
3
Overview of IO-Link Data and Functions (continued)
3.4
System Commands
Command Value
0x80 (128)
0x81 (129)
0x82 (130)
0xA5 (165)
0xA7 (167)
0xA8 (168)
0xA9 (169)
0xAC (172)
0xAF (175)
0xC0 (192)
Tab. 3-2:
System Commands – Overview
14
english
Device Action
Device Reset – Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values.
Application Reset
Reset Factory Settings
Maintenance Reset
Statistics Reset – Resets all output parameters to 0 and all user settings to the default values.
Statistics Start min/max/avg – Starts the statistics of the minimum value/maximum value/average
calculation.
Statistics Stop – Stops statistics operation completely.
Statistics Start Moving Average – Starts the statistics of the moving average calculation.
Start Ping
Set Reference Orientation – Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis