BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
6
System Functions (continued)
Namur Standard
(BIS M-4A3-082-401-07-S4
BIS M-4A6-082-401-07-S4
BIS M-4A7-082-401-07-S4)
Name
Ping
Short Circuit Pin 2 / Pin 4
Failure
Teach In
Maintenance Required
Bad Signal Quality
Out of Specification
Function Display
Communication
Ready Diagnosis On
Ready Diagnosis Off
Tab. 6-16: LED meaning and configuration – Namur Standard
www.balluff.com
Signal
Blue, flashing, 3 Hz
Red, flashing, 3 Hz
Red, static
Red, static
Blue, static
Orange, flashing, 1 Hz
Yellow, flashing, 3 Hz
Yellow, alternating with
green in a ratio of 10:1, 1 s
period
Green, alternating with
LED off in a ratio of 10:1,
1 s period
Green, static
Static white
Meaning
The ping can be activated via a system command to find
the device again.
Short circuit at pin 2 or pin 4
General error
The sensor is currently in Teach-In mode
Maintenance must be performed. Threshold value of
inclination is exceeded (default: Function switched off).
Poor signal quality (number of bad data carrier accesses)
The device is operated outside of specifications.
CP signal (data carrier within RFID range)
IO-Link communication is active. The device is ready.
The device is ready. Diagnosis functions are on.
The device is ready. Diagnosis functions are switched off.
english