Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS M-4A3-082-401-07-S4 Anleitung Seite 113

Industrial rfid-system
Vorschau ausblenden Andere Handbücher für BIS M-4A3-082-401-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS M-4A_-082-401-07-...
Industrial RFID-System BIS M
6
System Functions (continued)
Namur Standard
(BIS M-4A3-082-401-07-S4
BIS M-4A6-082-401-07-S4
BIS M-4A7-082-401-07-S4)
Name
Ping
Short Circuit Pin 2 / Pin 4
Failure
Teach In
Maintenance Required
Bad Signal Quality
Out of Specification
Function Display
Communication
Ready Diagnosis On
Ready Diagnosis Off
Tab. 6-16: LED meaning and configuration – Namur Standard
www.balluff.com
Signal
Blue, flashing, 3 Hz
Red, flashing, 3 Hz
Red, static
Red, static
Blue, static
Orange, flashing, 1 Hz
Yellow, flashing, 3 Hz
Yellow, alternating with
green in a ratio of 10:1, 1 s
period
Green, alternating with
LED off in a ratio of 10:1,
1 s period
Green, static
Static white
Meaning
The ping can be activated via a system command to find
the device again.
Short circuit at pin 2 or pin 4
General error
The sensor is currently in Teach-In mode
Maintenance must be performed. Threshold value of
inclination is exceeded (default: Function switched off).
Poor signal quality (number of bad data carrier accesses)
The device is operated outside of specifications.
CP signal (data carrier within RFID range)
IO-Link communication is active. The device is ready.
The device is ready. Diagnosis functions are on.
The device is ready. Diagnosis functions are switched off.
english
53

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis