Secondary Device Functions (continued)
Current Operating Hours
This parameter saves the value of the operating hours
since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours
since the first commissioning in seconds.
Custom Operating Hours
This parameter saves the value of the operating hours
since the last reset in seconds.
Operating Hours Saving Mode
The current storage behavior can be set.
Value
Meaning
0x00 (0)
Dynamic
0x01 (1)
Static
Tab. 5-12: Operating hours counter – Operating hours saving mode
30
english
Description
The first save operation is
performed 1 minute after
switching on; the storage
interval than doubles after
every save operation. This is
limited to a storage interval
of 12 minutes. The intervals
are 1, 2, 4, 8, 12 minutes.
Operating hours counters
are stored every 12 minutes.
5.2.5
System Commands
Command Value
Device Action
0x81 (129)
Application Reset – Resets
Custom operating hours to the
default value.
0x82 (130)
Reset Factory Settings – Resets
Custom operating hours and
Operating hours saving mode to
the default value.
0xA5 (165)
Maintenance Reset – Resets
Custom operating hours to the
default value.
Tab. 5-13: Operating hours counter – System Commands
For an overview of all System Commands, see section 3.4
on page 14.