Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Moretti Forni evolution S-Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 40
reference feet of each unit into the housing on the one underneath it
(item A - fig.5).
NOTE:
In case of structures with spacer ring (possible only
with cell), proceed as follows:
- remove the cell wheels and fit them under the spacer ring, in the
relevant position, as shown;
- in case of equipment rail, remove the bottom support surface (fig.
5.3 part A) and refit this once the structure has been completed;
- stack the cell without wheels onto the spacer ring and use the clips
and screws provided to secure it in place (fig.5.3 part.B);
- continue to stack as illustrated in fig.5.
Once correctly stacked, remove the screws on the top crosspiece of the
chamber module and replace them with the longer screws provided, as
illustrated in fig 5.1.
Then tighten the top extractor hood unit onto the chamber underneath,
as shown in figure 5 part.B.
WARNING!
For the correct operation of the appliance,
screw the relevant plugs (provided) into the projecting sections (left
and right) on the bottom baking element (item C - Fig.5.2).
The oven must also be positioned in a well-aired room, at a distance of
at least 10 cm from the left side wall and from the rear wall, and of 50
cm from the right side wall (Fig.6).
This distance of 50 cm is essential in order to guarantee access during
maintenance operations.
Take into account that for certain cleaning/maintenance operations, the
distance needs to be greater than stated here and therefore, consider the
possibility to be able to move the oven for the purpose of carrying out
these operations.
2.5
CONNECTIONS
2.5.1
VAPOUR EXHAUST CONNECTION
WARNING!
Connection of the vapour exhaust must only
be carried out by specialised personnel.
The exhaust pipe for the vapour discharged after the opening of the
special valve (see 3.4.1) is on the back of the oven (item C - fig.7). The
rear vapours are channelled together with the front vapours that form
after the door is opened inside the hood and they are issued through the
special vapour exhaust hole (item B – fig.7).
NOTE:
It is recommended that you connect the vapour
exhaust to a flue or to the outside using a pipe with a minimum
diameter of 150 mm.
This pipe needs to be inserted (item A - fig.7) into the oven exhaust
pipe. Any extensions must also be connected so that the upper pipes fit
into the lower ones, as illustrated for the connection described above. If
the external vapour exhaust pipe is very long, it is advisable to fit a
small plastic tube at the base of the pipe itself to drain off any
condensation (fig.7 item D). This operation must be carried out before
coupling the pipe to the outlet.
2.5.2

ELECTRICAL CONNECTION

WARNING!
Electrical connection must only be carried out
by specialised personnel, in compliance with current local state
Electric Quality Assurance Corporation requirements.
Before starting the connection procedure, check that the earthing
system is provided in accordance with European EN standards.
Before starting the connection procedure, check that the main
power switch for the supply to which the oven is to be connected
has been turned to the "off" position.
The rating plate contains all the information necessary for proper
connection.
2.5.2.1 ELECTRICAL CONNECTION OF THE BAKING
CHAMBER
WARNING!
Each of the baking chambers must be fitted
with a main four-pole switch with fuses or an automatic switch
suitable for the values shown on the plate, to allow the single
appliances to be disconnected from the mains, that provide full
disconnection under overvoltage category III conditions.
NOTE:
The device selected should be in the immediate vicinity
of the oven and within easy access.
The baking chamber is delivered with the required voltage indicated on
the rating plate (fig.1).
To carry out electrical connection, remove the protective cover located
on the rear side of the baking chamber (fig. 8). The connection cable
must be supplied by the installer.
When connecting to the power mains, it is necessary to fit a plug that
complies with the standards and regulations in force.
Insert a cable with an adequate cross-section (see technical data) into
the cable raceway provided (fig.9 part B) and connect it to the terminal
board as shown in figures 10 and 11, respectively.
Moreover, these appliances must be connected to the unipotential
system (fig.9 partA): a terminal is provided for this purpose at the back
of the appliance. It is marked with the following symbol TERMINAL
FOR THE UNIPOTENTIAL SYSTEM.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±10%.
WARNING!
supply must have characteristics at least equal to the model with
rubber insulation H07RN-F and must have a rated section suited to
the maximum absorption (see technical data).
WARNING!
earthed. A special earth terminal has been provided for this
purpose on the connection terminal board (fig. 10-11). It is marked
with the earth symbol and the earth wire must be connected to it.
2.5.2.2 PROVER ELECTRICAL CONNECTION
WARNING!
two-pole switch with fuses or an automatic switch suitable for the
values shown on the plate.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
The leavening compartment is delivered with a voltage of 230Vac. 1N
50/60 Hz, as indicated on the rating plate at the side (fig. 1).
To carry out electrical connection, remove the protective cover located
on the rear side of the compartment (fig.12).
The connection cable must be supplied by the installer.
When connecting to the power mains, it is necessary to fit a plug that
complies with the standards and regulations in force.
Insert a cable with an adequate cross-section (see technical data) into
the cable raceway provided (fig.13 part B) and connect it to the
terminal board as shown in figure 14.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±10%.
WARNING!
supply must have characteristics at least equal to the model with
rubber insulation H07RN-F and must have a rated section suited to
the maximum absorption (see technical data).
WARNING!
earthed. A special earth terminal has been provided for this
purpose on the connection terminal board (fig. 14). It is marked
with the earth symbol and the earth wire must be connected to it.
Moreover, these appliances must be connected to the unipotential
system (fig.13 partA): a terminal is provided for this purpose at the
back of the appliance. It is marked with the following symbol
TERMINAL FOR THE UNIPOTENTIAL SYSTEM.
2.5.2.3 VAPOUR
CONNECTION
WARNING!
two-pole switch with fuses or an automatic switch suitable for the
values shown on the plate.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
The vapour aspiration hood is delivered with a voltage of V230 1N
50/60 Hz, as indicated on the rating plate at the side (fig. 1).
UK/3
The flexible wire for connection to the power
It is essential that the appliance be properly
The compartment must be fitted with a main
The flexible wire for connection to the power
It is essential that the appliance be properly
ASPIRATION
HOOD
The compartment must be fitted with a main
ELECTRICAL

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

S100eS120eS125e

Inhaltsverzeichnis