6159932190
Issue no: 02
Power
Safety angle
Sensitivity
Station
Torque reset
62 / 62
Original instructions
This is the word used to define the maximum current and therefore the maximum
torque allowed in a phase. It is expressed as a percentage of the maximum current for
a given tool.For instance, 100% corresponds to the full power available to run a phase.
50% indicates that the tool will not be able to supply more than 50% of its maximum
torque. The Torque / Power correlation is given for information. There is no calibration
between these magnitudes.
This is a torque value which causes the tool to stop when the said value is reached
whereas all the other stop conditions have failed. This applies to the strategies where
the stop magnitude is different from the torque. The safety torque allows you to protect
the tool or the joint in the event of a fault.
Sensitivity is a coefficient expressed in mV/V which indicates the value of the signal
generated by the torque transducer when the said transducer is supplied with 1 V and
for a torque equal to the "nominal load". This data is stored in the tool. The unit reads
the sensitivity each time it is switched on and each time there is a tool change in order
to constantly compute the correct torque value. This data can be displayed but cannot
be modified.
A station is a combination of tools operating together in a synchronous mode. The
simplest station consists of one tool only. The maximum number of tools depends on
the system. An overall report is produced for the station.
This is the action for resetting the torque value. It is usually performed at the beginning
of thecycle for the whole cycle but it can also be performed at the beginning of any
phase of the cycle. In the latter case, the final torque report takes the events into
account from the latest Resetting action.