Symptoms
The tool does not always start. Faulty contact in the trigger
Seen from the controller side,
the tool does not reach the
programmed torque or hardly
reaches it.
The motor overheats.
The tool is stopped by the
"maximum current" instruction.
Dispersion or abnormal
deviation in the tightening
results.
The tool does not run in run
reverse mode.
The tool does not run in
tightening mode, but runs in
run reverse mode.
60 / 62
Original instructions
Possible causes
switch.
The angle-head efficiency has
deteriorated to a large extent.
The "memory" board is faulty.
Motor issue caused either by
● Damaged stator (motor
failure).
● Faulty cable.
● Faulty servo-driver.
The tuning of the resolver is
disturbed(motor failure).
The angle head is faulty.
Transducer or internal
connections damaged.
The Tightening / Untightening
reversing gearbox is faulty.
The run reverse speed is set
to 0.
Loss of controller memory.
Transducer fault.
The Tightening / Untightening
reversing gearbox is stuck in
run reverse mode.
N° Check
21 In the "Maintenance - Inputs/Outputs" menu,
check the switching of the concerned input.
If there is a fault, please contact your local
customer center.
23 If the wear of the angle head is low, a
dynamic calibration could compensate the
drift.
If not, please contact your local Customer
Center for a maintenance.
24 Please contact your local Customer Center.
25 Check that the contacts of the motor
connector or of the cable are neither twisted
nor pushed back.
Replace the servo driver.
If the problem is not solved, please contact
your local customer center.
26 No check is possible. Rule out every other
possible cause.
Please contact your local customer center
for maintenance.
27
This can be confirmed by checking the
torque ripple of the "torque versus time"
curve saved in the unit.
If so, please contact your local Customer
Center
28
Please contact your local Customer Center.
30
In the "Tests, Inputs/outputs" menu, check
the switching of bit 7 when the reversing
gearbox is activated.
Check the "Spindle validation on run reverse"
parameter.
Test commutation between pins 2 and 5 of
the tool connector.
Check the value of the run reverse speed
in the "Parameters/Station" menu. If the
reversing gearbox is running correctly, the
tool LEDs should blink.
32
Check the presence of tightening cycles.
Check that the selected cycle is programmed
correctly.
33
Refer to No. 18.
34
Refer to No. 30.
CVIC II