Herunterladen Diese Seite drucken

Desoutter CVIC II Bedienungsanleitung Seite 57

Vorschau ausblenden Andere Handbücher für CVIC II:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 192
CVIC II
Text
Comments
NOT READy
List of errors preventing the CVIC from being ready:
● Over-current: Maximum servo drive current is reached.
● Differential: Earth ground connection opened (the CVIC does not check earth linkage). This
● Thermal contact: Maximum motor temperature is reached (100°C). This error remains
● SPI link error: The cycle was aborted due to a digital communication problem (SPI)
● FLEX version error
● Maximum current (Imax)
● Resolver: Position change or non zero speed detected when the motor start is not
● Temperature: Power components over temperature.
Svr
The cycle was aborted following a Servo drive error:
● Over-current: The maximum servo drive current is reached.
● Differential: The earth ground connection is opened (the CVIC does not check earth
● Thermal contact: The maximum motor temperature is reached (100°C). The error is
● SPI link error: The cycle was aborted due to a communication problem through the digital
● FLEX version error (FLEX)
● Maximum current (Imax)
● Resolver: Position change or non zero speed detected when the motor start is not
● Temperature: Power components over temperature.
NOTE: All these errors deactivate the READY signal as long as the error exists.
Over current
Maximum servo drive current is reached. In this case, the motor cannot start again.
Overall, it induces a Servo drive error, then a detailed Over-current error.
Differential
Earth tool connection fault (the CVIC doesn't check earth linkage).
This error is often due to a cable problem.Overall, it induces a Servo drive error, then a
detailed Differential error.
Thermal contact
Maximum motor temperature reached (100°C).
The fault is activated as long as the motor temperature doesn't fall below 80°C again. Overall,
it induces a Servo drive error, then a detailed Thermal contact error.
general
● Over-current: The maximum servo drive current is reached
● Differential: The earth ground connection is opened (the CVIC does not check earth
● Thermal contact: The maximum motor temperature is reached (100°C).
SPI link
The cycle was aborted following a digital (SPI) link fault between the controller and the tool.
This fault removes instantaneously the READY signal of the machine (it is checked every 10
ms). Overall, it induces aServo drive error, then a detailed SPI error.
● When in the Checking channel menu we get:
● When in START SPINDLE mode the motor is stopped.
● When in TEST and CURRENT CALIBRATION mode: no action.
04/2010
Original instructions
error is often due to a cable problem.
activated until the motor temperature falls below 80°C.
between the controller and the tool.
activated.
linkage). This problem is often due to a cable problem.
activated as long as the motor temperature does not fall below 80°C.
link (SPI) between the controller and the tool.
activated.
WARNINg: When in MAINTENANCE \ TEST \ START SPINDLE mode, this error
does not prevent the motor from working.
OR
linkage). This problem is often due to a cable problem
OR
The error is activated as long as the motor temperature does not fall below 80°C.
-
Tool error : Tool link (EEPROM)
-
Servo drive error
6159932190
Issue no: 02
55 / 62

Werbung

loading