E05
Spindle is idle on a start signal.
No Spindle validation signal on the I/O port if the Spindle validation box is activated in the
STATION menu.
Tool will run only if the Spindle validation signal is activated on the I/O port.
E06
Start cycle arrives when the controller is not ready (may be due to a tool change, a Servo
drive error, etc. that has not been reset).
E07
Spindle is disabled after a Reject report.
If the Stop on bad report box in the STATION menu is activated, then the tool will be disabled.
To enable it, it is necessary to activate the Failure acknowledge input on the I/O port.
e09
CVINET FIFO is full.
The cycle can start but there is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
E09
CVINET FIFO is full.
The cycle can not start because the Locking on when FIFO is full option is validated and there
is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
e12
ToolsNet FIFO is full.
The cycle can start but there is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
E12
ToolsNet FIFO is full.
The cycle can not start because the Locking on when FIFO is full option is validated and there
is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.

11.3 - Operating problems due to adjustment problems

Symptoms
The tool starts then stops
immediately without running
the rundown speed cycle.
The tool skips the rundown
sequence.
Seen from the controller side,
the tool does not reach the
programmed torque or hardly
reaches it.
04/2010
Original instructions
Possible causes
The "stall torque" instruction is
too low.
The programmed current is too
low.
The acceleration time is
too short compared to the
maximum time.
The maximum time is too short
or null.
A machine part impedes the
rotation of the tool.
The "current" instruction is too
low.
The acceleration time is too
short.
The rundown instruction is too
low.
The maximum rundown time is
too short.
The spindle is not validated in
the sequence.
The power programmed during
the relevant phase is not
sufficient.
The tool is not suited to the
task.
N° Check
01 Check the values programmed for the run
down and final speed sequences.
02 Please contact your local Customer Center.
03 Check the values programmed for the run
down sequence.
04 Check and increase the programmed value if
necessary.
05 Check that the tool performances are
compatible with the required torque.