Herunterladen Diese Seite drucken

Bottom Panel; Initial Start Up; Installation; Stop Signal - Desoutter CVIC II Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CVIC II:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 192
6159932190
Issue no: 02

3.5 - Bottom panel

1
3
Legend
1
RS232 port, SubD 9 points: PC connection, bar code
or printer
- PC cable ref.: 6159170470
- Printer cable ref.: 6159170110
2
Ethernet port
3
8 inputs / 8 Outputs connector for PLC or indicator box
or socket tray connection, it includes the STOP signal
4
ON / OFF switch, over current protection and ground
fault protection
5
Tool connection
6
Mains power inlet
7
Field bus module (optional)
8 / 62
Original instructions

4 - INITIAL START uP

4.1 - Installation

7
Before switching on, make sure that the
2
controller is installed in accordance with
the installation and safety instructions
mentioned in this manual, see "Safety
instructions", page 4.

4.1.1 - STOP signal

4
Check that the "STOP" signal is correctly connected to
the Input connector of the controller. The STOP can be
connected either to the PLC, or to a push-button close to
the tightening station.
If not connected, check that the jumper is correctly
positioned.
5
OR
1
1
2
2
3
3
4
4
6
The opening of the STOP contact disables the power
circuit. Note that it is recommended to wire the STOP
when using handheld tools, but that it is absolutely
necessary for fixed tools.

4.1.2 - Switch OFF

2
CVIC II
1
13
1
OFF
04/2010

Werbung

loading