Herunterladen Diese Seite drucken

Printing Format For Tightening Results; Pc2 Format; Pc3 Format - Desoutter CVIC II Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CVIC II:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 192
6159932190
Issue no: 02
8 - PRINTINg FORMAT FOR
TIghTENINg RESuLTS

8.1 - PC2 format

Char
Designation
number
1
char. <CR>
2
range or cycle number
2
fastener number
3
"T=+"
5
torque in 1/10 of Nm
1
<LF>
1
" "
1
<CR>
2
range or cycle number
2
fastener number
3
"A=+"
5
angle in 1/10 of degree
1
<LF>
1
" "
1
<CR>
2
range or cycle number
2
fastener number
3
5
1
<LF>
1
" "
Example of result:
<CR>0109T=+00400<LF> <CR>0109A=+01200<LF>
<CR>0109TR=+00580<LF>
The last result in the list ends with <LF><LF> instead of
<LF>""
46 / 62
Original instructions

8.2 - PC3 format

Char
Designation
number
1
char. A (frame type)
3
station number (1 to 250)
3
port number (1 to 32)
configuration (A to O correspond to
1
configurations 1 to 15)
1
Z (system identifier)
1
char. A (frame type)
1
report code (see chart below)
6
date (year, month, day)
6
time (hour, minute, second)
8
torque
5
angle
1
<CR>
Checksum (modulo sum 256 of the previous
1
characters) not calculated for the moment
1
<LF>
The last result in the list ends with <LF><LF> instead of
<LF>
Report code: ASCII code 0100 :
1
2
X
X
X
Legend
1
1 = max. angle
2
1 = min. angle
3
1 = max. torque
4
1 = min. torque
According to the various combinations, the following
characters will be obtained:
@
accept torque
A
min. torque
B
max. torque
D
accept torque
E
min. torque
F
max. torque
h
accept torque
I
min. torque
J
max. torque
on servodrive fault
or spindle belonging to reject group
0x00
or cycle start drop
or cycle not completed for spindle
or transducer fault
Example of result:
A001001BZ@92120811021500041.7500121<CR>
<CS><LF>
CVIC II
3
4
X
accept angle
accept angle
accept angle
min. angle
min. angle
min. angle
max. angle
max. angle
max. angle