Parameter
Comment
Max.time
Phase running time out: 0.01 - 99 s.
Int.time
Time programmed between this phase
and the next one: 0 - 20 s.
Strategy
Torque/Torque+Angle/Angle+Torque.
Min T
Minimum torque: 0 Nm to maximum
value of the spindle.
Target T
Target torque: 0 Nm to maximum value
of the spindle (torque or torque + angle
strategy).
Max T
Maximum torque: 0 Nm to maximum
value of the spindle.
Safety T
Safety torque: 0 Nm to maximum value
of the spindle.
B-away T
Breakaway torque: starts the torque
control (strategies: torque or torque
+ angle), must be higher than final
torque.
Threshol
Angle threshold: 0 Nm to maximum
value of the spindle.
Min A
Minimum angle: 0 - 9,999°.
Target A
Target angle: 0 - 9,999° (angle +
torque strategy).
Max A
Maximum angle: 0 - 9,999°.
Other...
See motor parameters.
Detailed RP: See "Tightening strategy guide",
page 50" (torque, torque + angle, angle + torque
and prevailing torque).
22 / 62
Original instructions

5.3.5.8 - Motor parameters

Parameter
Fc(hz)
Thread
Speed
Acceler
Reset
External stop Yes/No, the following conditions must
CVIC II
Comment
Bandwidth adjustment from 4 to
128Hz. Reducing this value allows you
to filter the defects in the Torque signal
and improve the dispersion of the
torque installed (Cp or Cam), which
may be useful in particular when using
a Crowfoot head.
Warning: as a result, the adjustment
of the torque (Cpk) may be modified.
It can be adjusted by calibrating the
tool on the assembly ("CALIBRATION
menu", page 41).
The cut-off frequency value
entered will have no effect
on ECPHT tools.
Right / Left.
Rotational speed: 0 - 100%.
0 - 20 s. Acceleration or deceleration
time to switch from one speed to
another, this parameter is enabled for
the first phase and when the inter-
phase time is not equal to zero. When
the inter-phase time is equal to zero,
acceleration is optimized automatically.
The Reset function allows you to reset
the torque and/or angle values at the
beginning of the current phase.
be met for the system to stop the
current phase and shift to the next
one:
● The External Stop parameter must
be on Yes in this screen.
● The signal at the External Stop
input of the Input/Output connector
must shift to 1.