FLEX version
The FLEX software version is lower than the one necessary for the application version.
This fault can only appear after a software upgrade.
Nevertheless, the delivered software automatically upgrades the FLEX software version.
When this fault occurs:
● It is not possible to start the motor in Normal mode.
● It is possible to start the tool in Test mode.
● It is possible to calibrate the tool manually or automatically.
● It is possible to adjust the resolver offset.
Overall, it induces a Servo drive error, then a detailed FLEX version error.
Imax
The cycle was aborted because the maximum tool current is reached.
This over consumption may also be due to short-circuit, a cable fault, a resolver fault or an
offset resolver fault.
Reading EEPROM
Indicates an access error to the tool's EEPROM memory:
Writing
When one of the following operations is wrongly carried out:
● Log out / Data writing / Data re-reading / Data recorded comparison
Reading
When switched on, the CVIC carries out a complete memory check
● CRC of the parameters: TOOL PROGRAMMING ERROR
● Parameter version: TOOL VERSION ERROR
● Parameter changing: CHANGE OF TOOL
● Counter CRC: TOOL PROGRAMMING ERROR
● Tool cycle CRC: TOOL PROGRAMMING ERROR
● Cycle 0 CRC: TOOL PROGRAMMING ERROR
● Torque/Current table CRC: TOOL PROGRAMMING ERROR
● Controller/Tool compatibility: CURRENT TRANSDUCER INCOMPATIBLE WITH TOOL
Resolver
Position change or non zero speed detected when the motor start is not activated.
Only checked in Test mode.
Temperature
Indicates power components (IGBT) over temperature.
The temperature is measured on the power components' cooling radiator.
When the temperature exceeds 75 °C, the error is activated and remains until the temperature
returns below70°C.
Note that this measure also starts the internal fan from 60°C onwards and stops the fan when
the temperature returns below 50°C.
Overall, it induces a Servo drive error, then a detailed Temperature error.
Prg
The cycle was aborted due to a programming fault.
For example: the programmed torque is higher than the tool capacity.
Ext
The cycle was aborted due to activation of the EXTERNAL STOP signal (if this option is
selected in the concerned phase).
Tool programming
Tool memory parameters are wrong.
Tool version
The tool memory parameter version is not compatible with the CVIC software version.
Tool link
Tool memory parameter reading is impossible.
Current transducer
The connected tool is not compatible with the CVIC model
incompatible with
(e.g.: ECA60 connected to CVIC-2).
tool
E02
Controller busy (for example: down-loading or up-loading in progress).
E03
Batch of cycle complete (number of cycles OK) if the Lock on NCYOK box (lock after a batch
of cycle complete) in the STATION menu is activated.
E04
No cycle number validated on controller OR non-existing cycle number requested on the I/O
port.