CVIC II

9.3 - Angle control and torque monitoring

For CVIC II this strategy allows to rotate by N degrees a
bolt over the angle threshold.
Angle
Torque
Max
Min
Max
Min
Angle
threshold
The recorded values are the following:
final torque and final angle
Spindle stop
● IF angle ≥ target angle
● OR torque > max. torque
Accept report
● IF min. torque < final torque < max. torque
● IF min. angle < final angle < max. angle
04/2010
Original instructions
Final torque
Final angle
Time
Tightening + spindle
torsion
Angle measured
during spindle back torsion
(up to angle threshold)

9.4 - Prevailing torque control

This phase allows you to check the residual torque
(prevailing torque) that results, for instance from the
thread formed with tapping screws.
It is useful to know if the thread is formed correctly
during the desired number of rotations without untimely
locking or tapping deficiency.
The initial time out allows you to start the readings when
the tool speed is stabilised.
The memorised result is the mean of the torque readings
during the acquisition phase.
The system stops the acquisition of the torque and angle
when the motor stops.
The torque pulse at the motor stop is not taken into
account.
Angle
Torque
Safety
Max
Mean torque
Min
Rise delay
time or angle
Spindle stop
● IF angle ≥ target angle
● OR torque > safety torque
Accept report
● IF min. torque ≤ torque ≤ max. torque
6159932190
Issue no: 02
Target angle
Time
Data aquisition