SAFETY

This device may be used by children who are at
least 8 years old, by people with reduced physi-
cal, sensory or mental capacities or those without
knowledge or experience, if they are properly su-
pervised and if the instructions relating to using
the device completely safely have been given to
them and the associated risks have been under-
stood. Children must not play with the device.
Cleaning and maintenance undertaken by the
user must not be carried out by unsupervised children.

1 .1 Identification of warnings

Symbol
DANGER
This term defines a high risk of dan-
ger, which can lead to death or se-
rious injury, if not avoided.
WARNING
This term defines a hazard which
could cause a risk to the machine and
its operation, if it is not taken into
account
Dangerous area
This symbol, in combination with a
keyword, characterises hazards that
could lead to death or injury.
Dangerous voltage
This symbol, in combination with a
keyword, characterises dangers asso-
ciated with the voltage and provides
information on voltage protection.
Property damage
This symbol, in combination with the
keyword WARNING, characterises
dangers to the machine and its proper
operation.

1 .2 General points

This operating and installation manual contains im-
portant instructions to follow for the fitting, opera-
tion and maintenance of the SANICUBIC® pumping
station. Following these instructions guarantees
safe operation and prevents injury and property
damage.
Please follow the safety instructions in every sec-
tion.
Before
fitting
and
pumping
station,
user concerned must read and understand all these
instructions.

1 .3 Intended use

Only use the pumping station in the fields of appli-
cation described in this documentation.
• The pumping station must only be operated in
technically perfect conditions.
• The pumping station must only pump the fluids
described in this documentation.
• The pumping station must never operate without
pumped fluid.
• Never exceed the usage limits defined in the do-
cumentation.

1 .4 Qualification and training of staff

Commissioning and maintenance of this device must
be performed by a qualified professional. Please refer
to installation standard EN 12056-4.
Meaning
commissioning
the
qualified
installer/
1 .5 Safety instructions for maintenance, inspec-
tion and installation
• Any alteration or modification of the pumping station
will void the warranty.
• Only use original parts or parts recognised by the
manufacturer. The use of other parts may void the
manufacturer's liability for any resulting damage.
• Before working on the pumping station, switch it
off and unplug the pumping station's power plug.
• You must follow the procedure for shutting down
the pumping station described in this operating
manual.
This operating manual must always be available on
site so it can be accessed by qualified staff and the
operator.
1 .6 Risks and consequences of non-compliance
with the operating manual
Failure to comply with this operating and installa-
tion manual will result in the loss of warranty rights
and rights to damages.
2

TRANSPORT / TEMPORARY STORAGE / RETURNS / DISPOSAL

2 .1 Receiving inspection

• When receiving goods, check the condition of the pumping station's pac-
kaging.
• In case of damage, note the exact damage and immediately notify the dea-
ler in writing.

2 .2 Transport

Dropping the pumping station
Risk of injury if the pumping station is dropped!
w Keep the pumping station horizontal when moving it.
w Observe the indicated weight.
w Never suspend the pumping station by the power cord.
w Use suitable means of transport.
✓ The pumping station has been inspected to make sure there is no
damage due to transport.
Choose suitable means of transport according to the weight table
Table 1: Weight of the pumping station
Model
SANICUBIC® 1
SANICUBIC® 1 WP
SANICUBIC® 1 VX
SANICUBIC® 2 Classic
SANICUBIC® 2 Pro
the
SANICUBIC® 2 VX

2 .3 Temporary storage / Packaging

In the case of commissioning after an extended storage period, take the fol-
lowing precautions to ensure storage of the pumping station:
Wet, dirty or damaged openings and junction points .
Leaks or damage to the pumping station!
w Clear the pumping station's blocked openings at the time of installa-
tion.

2 .4 Returns

• Properly drain the pumping station.
• Rinse and decontaminate the pumping station, especially if it has transported
harmful, explosive, hot or otherwise dangerous liquids.

2 .5 Disposal

The device must not be disposed of as household waste and must be
disposed of at a recycling point for electrical equipment. The device' s
materials and components are reusable. The disposal of electrical and
electronic waste, recycling and recovery of any form of used appliances
contribute to the preservation of our environment.
14
Gross Weight
(including packaging
and accessories) [kg]
19.8
26.7
30
35.5
33
101