Resonances Any resonances at the usual excitation frequencies (1 x and 2 x rotational frequency,
66 of 331
5 Installation at Site
5 Installation at Site

5.1 Safety regulations

DANGER
Persons in the tank during pump operation
Electric shock!
Risk of injury!
Danger of death from drowning!
▷ Never start up the pump set when there are persons in the tank.
WARNING
Impermissible solid objects (tools, screws/bolts or similar) in the pump sump/inlet
tank during pump start-up
Personal injury and damage to property!
▷ Check the pump sump/inlet tank for impermissible solid objects before
flooding, and remove, if necessary.
5.2 Checks to be carried out prior to installation

5.2.1 Preparing the place of installation

Place of installation for stationary models
WARNING
Installation on mounting surfaces which are unsecured and cannot support the
load
Personal injury and damage to property!
▷ Use a concrete of compressive strength class C25/30 which meets the
requirements of exposure class XS1 to EN 206 .
▷ The mounting surface must be set, even, and level.
▷ Observe the weights indicated.
vane passing frequency) must be prevented both in the foundation and in the
connected piping, as such frequencies may cause extreme vibrations.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
Place of installation for transportable models
WARNING
Incorrect positioning / incorrect placing down
Personal injury and damage to property!
▷ Position the pump set vertically with the motor on top.
▷ Use appropriate means to secure the pump set against tilting and tipping over.
▷ Refer to the weights given in the data sheet/on the name plate.
▷ Adjust the handle position.
Sanipump VX 50