3. Warning: Do not run the motor in forced mode (by pressing the key on
the keypad) before putting the pump in water. Dry running damages the
grinding system.

5 .5 Decommissioning

1. Close the valve on the inlet pipes.
2. Drain the tank by pressing the forced mode button on the pump. Close
the valve on the discharge pipes.
3. Switch off the electrical power supply and record the installation.
4. Inspect the hydraulic parts and shredding blades (depending on the
model). Clean them if necessary.
5. Clean the tank.
6

OPERATION

6 .1 SANICUBIC® Control box
NOTE
This paragraph describes the operation of a control box for two
pumps. The control box is operated in a similar manner for one
pump.
Table 4: SANICUBIC® remote control box
1
Yellow mains supply LED
2
Red alarm LED
3
Forced mode Engine 1
4
Forced mode Engine 2
The LED lamps provide information on the operating state of the control box.
NOTE: On the SANICUBIC® 1, the control box is integrated on the top of the
station's tank.
The detection system must be vented. Connect the vent turbine to the sta-
tion's control box.
Figure 2: Ventilation of the SANICUBIC® control box
6 .1 .1 . Operation of the SANICUBIC® 1 control keypad (IP67)
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high, the alarm LED lights
up red + engine starts up. Furthermore, if this LED flashes red, it indicates a
detection problem for the normal water level (Long dip tube).
Time alarm:
If the motor runs continuously for more than 1 minute, the red alarm LED
lights up.
Mains alarm:
- If the LED for the mains power is off, there is no power supply.
- When the device is powered on again, the LED flashes green, indicating that
the mains voltage has temporarily disappeared.
2/ Alarm reset: The keypad key will only turn off the red LED or the flashing
mains LED (which turns to a constant green) if the problem that triggered the
alarm has been solved. It also allows you to stop the ringing of the remote
alarm control.
6 .1 .2 Operation of the SANICUBIC® 1 VX /SANICUBIC® 2 Classic /SANICU-
BIC® 2 Pro / SANICUBIC® 2 VX remote control box
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high: the siren is triggered
+ the red alarm LED lights up + both motors start-up. If this LED flashes red,
it indicates a detection problem for the normal water level (Long dip tube).
Time alarm:
If one of the two motors runs for more than 1 minute: the siren is triggered +
the red alarm LED lights up + the other engine starts-up.
Mains alarm:
In case of power failure (or when unplugging the device): the siren is trigge-
red + the red alarm LED lights up + the yellow mains LED blinks.
2/ General alarm reset:
If the problem that triggered one of the alarms above disappears, the siren
stops, but the red alarm LED remains lit as a reminder of the fact that the sys-
tem encountered a problem. Either of the two keypad keys will stop the siren
in all cases, but it will only turn off the red LED if the problem that triggered
the alarm has been resolved. Alarms from the remote box will also remain ac-
tive until the problem has been solved. This prevents the system from being
«abandoned» by default.
6 .2 SANICUBIC® alarm unit
To wall mount the unit, use the following figure as a guide:
6 .2 .1 Operation of the SANICUBIC® 1 / SANICUBIC® 1 WP/ SANICUBIC® 1
VX / SANICUBIC® 2 Classic /SANICUBIC® 2 VX wired alarm unit
The SANICUBIC® alarm unit does not require a separate power supply. The
power is supplied through the SANICUBIC®. In case of power failure, the
alarm unit's battery takes over.
Connection of the alarm unit to the device:
Connect the alarm cable directly to the unit.
1/ The red general alarm LED reproduces the operation of the red LED on
the base card.
2/ The yellow «mains» LED indicates the power status of the alarm unit
-Steady light = live SANICUBIC® connected to the mains supply
-Flashing = power failure on the SANICUBIC®
3/ The alarm unit sounds in the event of an alarm as long as the fault is pres-
ent. To stop the alarm, press the reset (*) button on the device's keypad or the
button under the alarm unit.
1
Table 5: SANICUBIC® 1 / SANICUBIC® 1 WP / SANICUBIC® 1 VX / SANICUBIC®
2 Classic / SANICUBIC® 2 VX alarm unit
1
Red general alarm LED
2
Yellow mains alarm LED (power supply indicator)
6 .2 .2 Operation of the SANICUBIC® 2 PRO HF alarm unit
Unit powered by an electrical socket .
Risk of death!
19
2
Reset (*)