06.2005
Designation
Order No.
Rated voltage
• Input
• Output
Rated frequency
• Input
• Output
Rated current
• Input
• Output
Motor rated power
Auxiliary power supply
Max. aux. current requirement [A]
• Standard version at 20 V
• Maximum version at 20 V
Pulse frequency fp
Load class II to EN 60 146-1-1
Base load current
Overload cycle time
Overload current
Overload duration
Extra short-time loading
Base load current
Overload cycle time
Overload current *)
Overload duration
Loses, cooling
Efficiency η (rated operation)
Power loss (fp = 2.5 kHz)
Cooling air requirement
Pressure drop
p
Sound pressure levels, types of construction, dimensions, weights
Sound pressure level
Dimensions
• Width
• Height
• Depth
Weight approx.
Siemens AG
6SE7087-6KP60
SIMOVERT MASTERDRIVES
6SE70...
24-7TP_0
[V]
[Hz]
[A]
55.9
47
[kW]
22
[V]
1.3
1.8
[kHz]
[A]
[s]
[A]
[s]
[A]
[s]
[A]
[s]
[kW]
0.41
[m³/s]
0.041
[Pa]
30
[dB(A)]
48
[mm]
180
360
260
[kg]
14.1
*) With a 1.6-fold overload in field weakening, the torque quality is reduced
due to a ripple of 300 Hz.
Table 12-4
Technical data of inverter (part 3)
Operating Instructions
Value
26-0TP_0
27-2TP_0
DC 510 (- 15 %) to 650 (+ 10 %)
3 AC 0 up to rated input voltage x 0,75
---
0 ... 500
70.2
85.7
59
72
30
37
DC 24 (20 - 30)
1.7 to 16.0 (see fig. "Derating curves")
0.91 x rated output current
300
1.36 x rated output current
60
0.91 x rated output current
300
1.6 x rated output current
30
0.49
0.61
0.061
0.061
30
30
59
59
180
180
360
360
260
260
14.5
14.7
Technical Data
1.7
2.1
12-5