Assembling and
mounting the unit
Designating the
optional board
Siemens AG
6SE7087-6KP60
SIMOVERT MASTERDRIVES
Close the right-hand side wall of the unit as follows
♦ Insert the right-hand side wall from above into the guide on the front
right-hand side.
♦ Swing back the side wall.
♦ Screw the side wall tight again by means of the two fixing screws.
Mount the unit as follows:
♦ Insert the unit into its mounting position from the front underneath
the DC link bus module.
♦ Lift the unit upwards until the DC link bus module is completely in its
original position again.
♦ Screw the unit tight to the mounting surface with the fixing screws.
♦ Interlock the DC bus module.
♦ Re-connect all previously removed connecting cables.
♦ Check all connecting cables and the shield to make sure they sit
properly and are in the correct position.
♦ To designate the optional board, insert the relevant designation
plate into the envisaged position on the front of the unit.
♦ When the voltage has been switched in, the software of the unit
recognizes which optional boards have been installed and you can
then commence start-up.