Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iCAT Betriebsanleitung Seite 43

Vorschau ausblenden Andere Handbücher für iCAT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
iCAT WH
6.4.2
Removing the cable assembly from the iCAT-WK adapter
1
2
1
Cable support
2
Cable binder
3
Control lead
Fig. 10
Mounting the ROBO WH cable assembly
1 Introduce control lead (3) into bore on the adapter.
2 Remove pneumatic line (4) to the clamping cylinder (9).
3 Cut off cable binder (2) at the cable support (1).
4 Remove the cable support (1).
5 Remove all lines of the cable assembly (5), (6), (7), (8) from the adapter or unscrew them.
Mounting takes place in reverse order.
6.5 Mounting the liner
NOTE
• New still unused wire guide liners have to be shortened to the actual length of the cable
assembly.
• For handling the wire guide, please observe the enclosed wire guide mounting
instructions.
• Strip 350 mm of the insulation sheathing of the liner, after determining the correct length.
3
4
9
4
Pneumatic line
5
Cable assembly line
6
Cable assembly line
6 Putting into operation
8
7
7
Cable assembly line
8
Cable assembly line
9
Clamping cylinder
3
4
5
6
EN - 19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis