Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iCAT Betriebsanleitung Seite 34

Vorschau ausblenden Andere Handbücher für iCAT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3 Product description
The following data only apply in connection with the iCAT WH:
Type
Type of
cooling
ROBO WH W300
liquid
ROBO WH W500
liquid
ROBO WH W600
liquid
Tab. 8
Product-specific torch data (EN 60 974-7) in connection with iCAT
1Applications above 360A are possible in connection with the liquid-cooled torches
ROBO WH W500 using a special power-water-cable. It is available upon request.
2Use of the liquid-cooled ROBO WH W600 requires a special power-water-cable. With applications
above 500 A a cable assembly with two power-water-cables is available upon request.
The load data were determined under standard conditions, at low to medium heat of reflection,
free air circulation and an ambient temperature of approx. 28°C When used under more
strenuous conditions, the load data must be reduced by 10-20%.
3.2 Abbreviations
ROBO WH
Tab. 9
Abbreviations
EN - 10
Load
Duty
cycle
CO
M21
2
A
A
%
320
300
100
1
1
360
340
100
2
2
500
500
100
Automatic welding torch, liquid-cooled
Wire
Gas
flow
Cooling
capacity
min.
mm
l/min
W
0,8 - 1.2
ca. 20
800
0,8 - 1.6
10-20
800
0,8 - 1.6
10-20
800
iCAT WH
Cooling data
Flow Flow
pressure
min.
min. max.
l/min bar
bar
1
1.5
3.5
1
1.5
3.5
1.5
1.5
3.5

Werbung