7.4.3 Electrical connection with integrated potentiometer

The Lambda Colonne wit potentiometer is supplied with an Amphenol device plug,
number of poles 6 + PE; series C16-1.
R
6
4
5
S1= Limit switch for traversing direction -extract-
S2= Limit switch for traversing direction -retract-
M= Permanent magnet motor
= Thermoswitch
R= Potentiometer
With (+) at connection 1 and (-) at connection 2: the electric cylinder moves in the direction:
extract.
You can change the direction of movement by reversing the polarity of the connections - No. 1
and No. 2.

7.4.4 Other electrical connections

Other electrical connections (e.g. potential-bound signal contacts, potential-free signal contacts,
signal contacts for intermediate lifting positions) are possible.
These modifications must be defined with Phoenix Mecano Komponenten AG.
Unauthorised modifications or changes to the electric cylinder are not permitted for
safety reasons.
Unauthorized conversions of or changes to the electric cylinder lead to the general
operating license of this electric cylinder expiring.
In this case, Phoenix Mecano Komponenten AG cannot be held liable.

7.4.5 Limit switch

The electric cylinder is equipped with two internal limits switches. When using controllers that are
intended for the electric cylinder, the limit switch prevents an overrunning the maximum lifting
height as well as overrunning the lower stop position.
When using another controller or direct and an incorrect supply of current, the electric cylinder
can traverse beyond the limit switches and lead to their destruction.
+