Error Codes; Operation / Welding; Mig Pulse - Mig Double Pulse - Mig/Mag Automatic - Jackle ProPuls 330 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DW. USB:
Error:
Weld:
Jobs:
Config.:
All:
UP USB:
Jobs:
Config:
All:
UPG. USB:
STW PM:
STW FE:
STW IR:
STW PS:

17.11 Error codes

All recognized errors in the display are shown with a duration in 00:00.00 (HRS:min:Sec)
The error codes are listed described in chapter 24.
In order to go back to a menu or leave the entire menu, repeatedly press the key MODE/MATERIAL.

18. Operation / welding

Before welding, please pay attention to the following points:
Check the diameter of the contact tips and the wire diameter, both must correspond.
Press the button wire feed in until the wire comes out of the torch tip.
Connect the gas hose to the gas cylinder and open the cylinder slowly.
Set the gas pressure on the pressure regulator to the appropriate value (approx. 1.3-1.7 bar)
Press the gas testing button and set the gas flow to a value between 8.5 and 20l/min
tip:
Wire diameter x 10
The system is ready to weld.
Anschluss up/down Brenner
Connection up/down torch
Wasserrücklauf 'rot-heiß' DN 5
water runback 'red-hot' DN 5
Wasservorlauf 'blau-kalt' DN 5
water flow 'blue-cold' DN 5
Workpiece socket
18.1 MIG PULSE – MIG Double PULSE - MIG/MAG automatic
NOTE:
All functions and parameters are exactly described under point 4 operating controls.
The functional sequence is described.
In these welding processes, it has to do with automatic welding sequences.
In order to facilitate operation, it is normally necessary to configure the right welding program and welding power.
All other parameters are regulated by the machine itself.
This allows operating personnel with little experience to achieve good welding results.
A variety of welding programs have already been saved in the machine.
(see program selection panel in the wire feed flap)
Operating manual
Read and save error file
Read and save welding data
Read and save jobs
Read and save machine settings
Read and save all 4 listed data sets
Save jobs in the machine
Save machine settings in the machine
Save all data in the machine
Update torch PCB
Update wire feed PCB software
Update robot interface software
Update main PCB software
e.g.: 1.2 mm x 10 = 12 l/min
Massebuchse
ProPuls
A
V
H OLD
TEST
F
X
ProPuls 330,400,500
Brenner
Zentralanschluss
Central
torch connection
Page 49

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Propuls 400Propuls 500Propuls 320 compact