Error number
Error description and possible diagnosis
E1.1
USER SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.2
TORCH SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.3
CALIBRATION SETTINGS MISSING (calibration file missing)
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.4
Not used
E1.5
Not used
E1.6
ELECTRODE SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.7
TIG SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.8
MIG/MAG SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.9
WELDER SETTINGS MISSING (welding settings missing)
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E2.0
SYSTEM ERROR
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E3.1
COOLING UNIT PRESSURE
The cooling unit is recognised by the welder but the pressure switch is not functioning.
- Check the water level and fill if required.
- Check the lines
- Check to see if the pressure switch is functioning
Delete this error by switching the unit off and on again.
E3.2
WELDING VOLTAGE SHORT CIRCUIT
The error occurs after a short circuit between the output terminals of the machine for
more than 1.2 seconds.
In order to remedy the error, the short circuit must be eliminated so that the voltage at
the torch exceeds the limit value. Now, the error is no longer displayed and the welding
unit goes back to the mode it was in before the error occurred. If the torch button is still
pressed, it must be released and then pressed again to continue the welding process.
Delete this error by switching the unit off and on again.
E3.3
MOTOR SPEED ERROR
The motor turns but the signal for the speed is missing.
Check the cable at the incremental encoder.
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
Operating manual