Herunterladen Inhalt Inhalt Diese Seite drucken

Jackle ProPuls 330 Betriebsanleitung Seite 66

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error number
Error description and possible diagnosis
E6.0
WF HOUSING CAN communication faulty (Wire feeder communication faulty)
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E6.1
ROBOT INTERFACE communication faulty
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E6.2
TORCH DISPLAY communication faulty
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E7.0
REMOTE error
An error is detected with the remote control.
- wrong remote control connected
- cable connection faulty
- Contact JÄCKLE customer service
If a functioning remote control is connected, the error is rectified on its own.
Delete this error by switching the unit off and on again.
AUT ADJ
This alarm occurs if the power limit value is exceeded. The alarm is shown every 1.5
Power Limit
seconds alternating along with the standard display. Nevertheless, the machine
continues to weld with a limited level of power whilst adhering to the values indicated on
the rating plate.
Operating manual