The desired welding current can be configured.
Furthermore, the following parameters can be changed individually.
Arc force
The arc-force function prevents the electrode sticking to the workpiece during welding, thus overheating
the electrode and making it unusable.
That means that the power source increases the welding current for a short period of time to prevent
adhesion and ensures a trouble-free welding process, even in the case of electrodes that are difficult to
weld (configure using the Fx button).
HOT start
Is an increase of the welding current during arc ignition. This increase should prevent lack of fusion at
the start of the welding seam and cold tacks.
(configure using Fx button)
Electrode material type
3 different types of electrodes can be welded.
Basic electrodes (basic), rutile electrodes (rutile) and stainless steel electrodes (Cr-Ni)
(configure using the Material button)
VRD display (Voltage Reduction Device)
VRD means voltage reduction at the output. This function applies a maximum level of
voltage of <13V at the terminals. However, this means reduced performance ignition
characteristics of the electrodes.
VRD OFF: Uo= 63V, VRD ON: Uo=13V
This function is deactivated by default.
In order to switch on VRD, the front plate has to be unscrewed when the unit is switched off and the
VRD jumper on the PCB just behind it has to be removed as shown in the figure.
Activation takes place by setting the jumper.
Using the following rule of thumb, an average for the level of welding current can be determined:
Welding current = 50 x (electrode diameter- 1 )
Example: 3.2 mm electrode

18.5 TIG welding with LIFT-ARC function / pulsed

NOTE:
All functions and parameters are exactly described under point Fehler! Verweisquelle konnte
nicht gefunden werden. control elements.
The functional sequence is described.
ATTENTION: In the welding process TIG, the no-load voltage is applied to both output sockets. Careful, risk of
short circuits!
Operating manual
I = 50 x (3.2 -1 ) = 50 x 2.2 = 110 A
Vorne / front